mirror of
https://github.com/PepperDash/Essentials.git
synced 2026-02-15 04:34:56 +00:00
feat: change to use Debug.LogMessage everywhere
This commit is contained in:
@@ -8,6 +8,7 @@ using Newtonsoft.Json;
|
||||
using Newtonsoft.Json.Linq;
|
||||
using PepperDash.Core;
|
||||
using PepperDash.Essentials.Core.Config;
|
||||
using Serilog.Events;
|
||||
|
||||
namespace PepperDash.Essentials.Core
|
||||
{
|
||||
@@ -22,12 +23,12 @@ namespace PepperDash.Essentials.Core
|
||||
{
|
||||
return JsonConvert.DeserializeObject<EssentialsControlPropertiesConfig>
|
||||
(deviceConfig.Properties["control"].ToString());
|
||||
//Debug.Console(2, "Control TEST: {0}", JsonConvert.SerializeObject(controlConfig));
|
||||
//Debug.LogMessage(LogEventLevel.Verbose, "Control TEST: {0}", JsonConvert.SerializeObject(controlConfig));
|
||||
}
|
||||
catch (Exception e)
|
||||
{
|
||||
|
||||
Debug.Console(0, "ERROR: [{0}] Control properties deserialize failed:\r{1}", deviceConfig.Key, e);
|
||||
Debug.LogMessage(LogEventLevel.Information, "ERROR: [{0}] Control properties deserialize failed:\r{1}", deviceConfig.Key, e);
|
||||
return null;
|
||||
}
|
||||
}
|
||||
@@ -98,7 +99,7 @@ namespace PepperDash.Essentials.Core
|
||||
}
|
||||
catch (Exception e)
|
||||
{
|
||||
Debug.Console(0, "Cannot create communication from JSON:\r{0}\r\rException:\r{1}",
|
||||
Debug.LogMessage(LogEventLevel.Information, "Cannot create communication from JSON:\r{0}\r\rException:\r{1}",
|
||||
deviceConfig.Properties.ToString(), e);
|
||||
}
|
||||
|
||||
@@ -115,7 +116,7 @@ namespace PepperDash.Essentials.Core
|
||||
var dev = GetIComPortsDeviceFromManagedDevice(config.ControlPortDevKey);
|
||||
if (dev != null && config.ControlPortNumber <= dev.NumberOfComPorts)
|
||||
return dev.ComPorts[config.ControlPortNumber];
|
||||
Debug.Console(0,Debug.ErrorLogLevel.Notice, "GetComPort: Device '{0}' does not have com port {1}", config.ControlPortDevKey, config.ControlPortNumber);
|
||||
Debug.LogMessage(LogEventLevel.Information, "GetComPort: Device '{0}' does not have com port {1}", config.ControlPortDevKey, config.ControlPortNumber);
|
||||
return null;
|
||||
}
|
||||
|
||||
@@ -130,7 +131,7 @@ namespace PepperDash.Essentials.Core
|
||||
{
|
||||
var dev = DeviceManager.GetDeviceForKey(config.ControlPortDevKey);
|
||||
|
||||
Debug.Console(0, "GetCecPort: device '{0}' {1}", config.ControlPortDevKey, dev == null
|
||||
Debug.LogMessage(LogEventLevel.Information, "GetCecPort: device '{0}' {1}", config.ControlPortDevKey, dev == null
|
||||
? "is not valid, failed to get cec port"
|
||||
: "found in device manager, attempting to get cec port");
|
||||
|
||||
@@ -139,7 +140,7 @@ namespace PepperDash.Essentials.Core
|
||||
|
||||
if (String.IsNullOrEmpty(config.ControlPortName))
|
||||
{
|
||||
Debug.Console(0, "GetCecPort: '{0}' - Configuration missing 'ControlPortName'", config.ControlPortDevKey);
|
||||
Debug.LogMessage(LogEventLevel.Information, "GetCecPort: '{0}' - Configuration missing 'ControlPortName'", config.ControlPortDevKey);
|
||||
return null;
|
||||
}
|
||||
|
||||
@@ -147,7 +148,7 @@ namespace PepperDash.Essentials.Core
|
||||
var inputsOutputs = dev as IRoutingInputsOutputs;
|
||||
if (inputsOutputs == null)
|
||||
{
|
||||
Debug.Console(0, "GetCecPort: Device '{0}' does not support IRoutingInputsOutputs, failed to get CEC port called '{1}'",
|
||||
Debug.LogMessage(LogEventLevel.Information, "GetCecPort: Device '{0}' does not support IRoutingInputsOutputs, failed to get CEC port called '{1}'",
|
||||
config.ControlPortDevKey, config.ControlPortName);
|
||||
|
||||
return null;
|
||||
@@ -164,13 +165,13 @@ namespace PepperDash.Essentials.Core
|
||||
}
|
||||
catch (Exception ex)
|
||||
{
|
||||
Debug.Console(1, "GetCecPort Exception Message: {0}", ex.Message);
|
||||
Debug.Console(2, "GetCecPort Exception StackTrace: {0}", ex.StackTrace);
|
||||
Debug.LogMessage(LogEventLevel.Debug, "GetCecPort Exception Message: {0}", ex.Message);
|
||||
Debug.LogMessage(LogEventLevel.Verbose, "GetCecPort Exception StackTrace: {0}", ex.StackTrace);
|
||||
if (ex.InnerException != null)
|
||||
Debug.Console(0, "GetCecPort Exception InnerException: {0}", ex.InnerException);
|
||||
Debug.LogMessage(LogEventLevel.Information, "GetCecPort Exception InnerException: {0}", ex.InnerException);
|
||||
}
|
||||
|
||||
Debug.Console(0, "GetCecPort: Device '{0}' does not have a CEC port called '{1}'",
|
||||
Debug.LogMessage(LogEventLevel.Information, "GetCecPort: Device '{0}' does not have a CEC port called '{1}'",
|
||||
config.ControlPortDevKey, config.ControlPortName);
|
||||
|
||||
return null;
|
||||
@@ -191,7 +192,7 @@ namespace PepperDash.Essentials.Core
|
||||
{
|
||||
var dev = DeviceManager.GetDeviceForKey(ComPortDevKey) as IComPorts;
|
||||
if (dev == null)
|
||||
Debug.Console(0, "ComPortConfig: Cannot find com port device '{0}'", ComPortDevKey);
|
||||
Debug.LogMessage(LogEventLevel.Information, "ComPortConfig: Cannot find com port device '{0}'", ComPortDevKey);
|
||||
return dev;
|
||||
}
|
||||
}
|
||||
@@ -205,9 +206,7 @@ namespace PepperDash.Essentials.Core
|
||||
{
|
||||
|
||||
[JsonConverter(typeof(ComSpecJsonConverter))]
|
||||
public ComPort.ComPortSpec ComParams { get; set; }
|
||||
|
||||
public string RoomId { get; set; }
|
||||
public ComPort.ComPortSpec ComParams { get; set; }
|
||||
|
||||
public string CresnetId { get; set; }
|
||||
|
||||
|
||||
Reference in New Issue