mirror of
https://github.com/PepperDash/Essentials.git
synced 2026-02-09 17:54:59 +00:00
Finalized IHasExternalSourceSwitching adding method for setting the ExternalSource State
Adds arguments for External Source type it the AddExternalSource() Adds subscription and parsing for External Source events
This commit is contained in:
@@ -1,45 +1,45 @@
|
||||
using System;
|
||||
using System.Collections.Generic;
|
||||
using System.Linq;
|
||||
using Crestron.SimplSharp;
|
||||
using Crestron.SimplSharpPro;
|
||||
using System;
|
||||
using System.Collections.Generic;
|
||||
using System.Linq;
|
||||
using Crestron.SimplSharp;
|
||||
using Crestron.SimplSharpPro;
|
||||
using Crestron.SimplSharpPro.DeviceSupport;
|
||||
using Newtonsoft.Json.Linq;
|
||||
using PepperDash.Essentials.Core.Config;
|
||||
|
||||
|
||||
using PepperDash.Core;
|
||||
|
||||
namespace PepperDash.Essentials.Core
|
||||
{
|
||||
|
||||
/// <summary>
|
||||
/// IR port wrapper. May act standalone
|
||||
/// </summary>
|
||||
public class IrOutputPortController : Device
|
||||
{
|
||||
uint IrPortUid;
|
||||
IROutputPort IrPort;
|
||||
|
||||
public ushort StandardIrPulseTime { get; set; }
|
||||
public string DriverFilepath { get; private set; }
|
||||
public bool DriverIsLoaded { get; private set; }
|
||||
|
||||
/// <summary>
|
||||
/// Constructor for IrDevice base class. If a null port is provided, this class will
|
||||
/// still function without trying to talk to a port.
|
||||
/// </summary>
|
||||
public IrOutputPortController(string key, IROutputPort port, string irDriverFilepath)
|
||||
: base(key)
|
||||
{
|
||||
//if (port == null) throw new ArgumentNullException("port");
|
||||
IrPort = port;
|
||||
if (port == null)
|
||||
{
|
||||
Debug.Console(0, this, "WARNING No valid IR Port assigned to controller. IR will not function");
|
||||
return;
|
||||
}
|
||||
LoadDriver(irDriverFilepath);
|
||||
using PepperDash.Essentials.Core.Config;
|
||||
|
||||
|
||||
using PepperDash.Core;
|
||||
|
||||
namespace PepperDash.Essentials.Core
|
||||
{
|
||||
|
||||
/// <summary>
|
||||
/// IR port wrapper. May act standalone
|
||||
/// </summary>
|
||||
public class IrOutputPortController : Device
|
||||
{
|
||||
uint IrPortUid;
|
||||
IROutputPort IrPort;
|
||||
|
||||
public ushort StandardIrPulseTime { get; set; }
|
||||
public string DriverFilepath { get; private set; }
|
||||
public bool DriverIsLoaded { get; private set; }
|
||||
|
||||
/// <summary>
|
||||
/// Constructor for IrDevice base class. If a null port is provided, this class will
|
||||
/// still function without trying to talk to a port.
|
||||
/// </summary>
|
||||
public IrOutputPortController(string key, IROutputPort port, string irDriverFilepath)
|
||||
: base(key)
|
||||
{
|
||||
//if (port == null) throw new ArgumentNullException("port");
|
||||
IrPort = port;
|
||||
if (port == null)
|
||||
{
|
||||
Debug.Console(0, this, "WARNING No valid IR Port assigned to controller. IR will not function");
|
||||
return;
|
||||
}
|
||||
LoadDriver(irDriverFilepath);
|
||||
}
|
||||
|
||||
public IrOutputPortController(string key, Func<DeviceConfig, IROutputPort> postActivationFunc,
|
||||
@@ -54,85 +54,85 @@ namespace PepperDash.Essentials.Core
|
||||
|
||||
|
||||
|
||||
/// <summary>
|
||||
/// Loads the IR driver at path
|
||||
/// </summary>
|
||||
/// <param name="path"></param>
|
||||
public void LoadDriver(string path)
|
||||
{
|
||||
if (string.IsNullOrEmpty(path)) path = DriverFilepath;
|
||||
try
|
||||
{
|
||||
IrPortUid = IrPort.LoadIRDriver(path);
|
||||
DriverFilepath = path;
|
||||
StandardIrPulseTime = 200;
|
||||
DriverIsLoaded = true;
|
||||
}
|
||||
catch
|
||||
{
|
||||
DriverIsLoaded = false;
|
||||
var message = string.Format("WARNING IR Driver '{0}' failed to load", path);
|
||||
Debug.Console(0, this, message);
|
||||
ErrorLog.Error(message);
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
/// <summary>
|
||||
/// Starts and stops IR command on driver. Safe for missing commands
|
||||
/// </summary>
|
||||
public virtual void PressRelease(string command, bool state)
|
||||
{
|
||||
Debug.Console(2, this, "IR:'{0}'={1}", command, state);
|
||||
if (IrPort == null)
|
||||
{
|
||||
Debug.Console(2, this, "WARNING No IR Port assigned to controller");
|
||||
return;
|
||||
}
|
||||
if (!DriverIsLoaded)
|
||||
{
|
||||
Debug.Console(2, this, "WARNING IR driver is not loaded");
|
||||
return;
|
||||
}
|
||||
if (state)
|
||||
{
|
||||
if (IrPort.IsIRCommandAvailable(IrPortUid, command))
|
||||
IrPort.Press(IrPortUid, command);
|
||||
else
|
||||
NoIrCommandError(command);
|
||||
}
|
||||
else
|
||||
IrPort.Release();
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Pulses a command on driver. Safe for missing commands
|
||||
/// </summary>
|
||||
public virtual void Pulse(string command, ushort time)
|
||||
{
|
||||
if (IrPort == null)
|
||||
{
|
||||
Debug.Console(2, this, "WARNING No IR Port assigned to controller");
|
||||
return;
|
||||
}
|
||||
if (!DriverIsLoaded)
|
||||
{
|
||||
Debug.Console(2, this, "WARNING IR driver is not loaded");
|
||||
return;
|
||||
}
|
||||
if (IrPort.IsIRCommandAvailable(IrPortUid, command))
|
||||
IrPort.PressAndRelease(IrPortUid, command, time);
|
||||
else
|
||||
NoIrCommandError(command);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Notifies the console when a bad command is used.
|
||||
/// </summary>
|
||||
protected void NoIrCommandError(string command)
|
||||
{
|
||||
Debug.Console(2, this, "Device {0}: IR Driver {1} does not contain command {2}",
|
||||
Key, IrPort.IRDriverFileNameByIRDriverId(IrPortUid), command);
|
||||
/// <summary>
|
||||
/// Loads the IR driver at path
|
||||
/// </summary>
|
||||
/// <param name="path"></param>
|
||||
public void LoadDriver(string path)
|
||||
{
|
||||
if (string.IsNullOrEmpty(path)) path = DriverFilepath;
|
||||
try
|
||||
{
|
||||
IrPortUid = IrPort.LoadIRDriver(path);
|
||||
DriverFilepath = path;
|
||||
StandardIrPulseTime = 200;
|
||||
DriverIsLoaded = true;
|
||||
}
|
||||
catch
|
||||
{
|
||||
DriverIsLoaded = false;
|
||||
var message = string.Format("WARNING IR Driver '{0}' failed to load", path);
|
||||
Debug.Console(0, this, message);
|
||||
ErrorLog.Error(message);
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
/// <summary>
|
||||
/// Starts and stops IR command on driver. Safe for missing commands
|
||||
/// </summary>
|
||||
public virtual void PressRelease(string command, bool state)
|
||||
{
|
||||
Debug.Console(2, this, "IR:'{0}'={1}", command, state);
|
||||
if (IrPort == null)
|
||||
{
|
||||
Debug.Console(2, this, "WARNING No IR Port assigned to controller");
|
||||
return;
|
||||
}
|
||||
if (!DriverIsLoaded)
|
||||
{
|
||||
Debug.Console(2, this, "WARNING IR driver is not loaded");
|
||||
return;
|
||||
}
|
||||
if (state)
|
||||
{
|
||||
if (IrPort.IsIRCommandAvailable(IrPortUid, command))
|
||||
IrPort.Press(IrPortUid, command);
|
||||
else
|
||||
NoIrCommandError(command);
|
||||
}
|
||||
else
|
||||
IrPort.Release();
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Pulses a command on driver. Safe for missing commands
|
||||
/// </summary>
|
||||
public virtual void Pulse(string command, ushort time)
|
||||
{
|
||||
if (IrPort == null)
|
||||
{
|
||||
Debug.Console(2, this, "WARNING No IR Port assigned to controller");
|
||||
return;
|
||||
}
|
||||
if (!DriverIsLoaded)
|
||||
{
|
||||
Debug.Console(2, this, "WARNING IR driver is not loaded");
|
||||
return;
|
||||
}
|
||||
if (IrPort.IsIRCommandAvailable(IrPortUid, command))
|
||||
IrPort.PressAndRelease(IrPortUid, command, time);
|
||||
else
|
||||
NoIrCommandError(command);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Notifies the console when a bad command is used.
|
||||
/// </summary>
|
||||
protected void NoIrCommandError(string command)
|
||||
{
|
||||
Debug.Console(2, this, "Device {0}: IR Driver {1} does not contain command {2}",
|
||||
Key, IrPort.IRDriverFileNameByIRDriverId(IrPortUid), command);
|
||||
}
|
||||
}
|
||||
}
|
||||
Reference in New Issue