fix: updated CEN-IO classes inheriting from EssentialsDevice to CrestronGenericBaseDevice to resolve activation issues

This commit is contained in:
jdevito
2022-08-31 14:43:58 -05:00
parent 40cb1b0fcf
commit fb689c4484
3 changed files with 76 additions and 69 deletions

View File

@@ -1,93 +1,93 @@
using System;
using System.Collections.Generic;
using System.Linq;
using System.Text;
using Crestron.SimplSharp;
using Crestron.SimplSharpPro;
using Crestron.SimplSharpPro.GeneralIO;
using PepperDash.Essentials.Core.Config;
using PepperDash.Core;
namespace PepperDash.Essentials.Core
{
/// <summary>
/// Wrapper class for CEN-IO-IR-104 module
/// </summary>
[Description("Wrapper class for the CEN-IO-IR-104 module")]
public class CenIoIr104Controller : EssentialsDevice, IIROutputPorts
using System;
using System.Collections.Generic;
using System.Linq;
using System.Text;
using Crestron.SimplSharp;
using Crestron.SimplSharpPro;
using Crestron.SimplSharpPro.GeneralIO;
using PepperDash.Essentials.Core.Config;
using PepperDash.Core;
namespace PepperDash.Essentials.Core
{
/// <summary>
/// Wrapper class for CEN-IO-IR-104 module
/// </summary>
[Description("Wrapper class for the CEN-IO-IR-104 module")]
public class CenIoIr104Controller : CrestronGenericBaseDevice, IIROutputPorts
{
private readonly CenIoIr104 _ir104;
private readonly CenIoIr104 _ir104;
/// <summary>
/// Constructor
/// </summary>
/// <param name="key"></param>
/// <param name="name"></param>
/// <param name="ir104"></param>
public CenIoIr104Controller(string key, string name, CenIoIr104 ir104)
: base(key, name)
{
_ir104 = ir104;
}
/// <param name="ir104"></param>
public CenIoIr104Controller(string key, string name, CenIoIr104 ir104)
: base(key, name, ir104)
{
_ir104 = ir104;
}
#region IDigitalInputPorts Members
/// <summary>
/// IR port collection
/// </summary>
public CrestronCollection<IROutputPort> IROutputPorts
{
get { return _ir104.IROutputPorts; }
public CrestronCollection<IROutputPort> IROutputPorts
{
get { return _ir104.IROutputPorts; }
}
/// <summary>
/// Number of relay ports property
/// </summary>
public int NumberOfIROutputPorts
{
get { return _ir104.NumberOfIROutputPorts; }
}
public int NumberOfIROutputPorts
{
get { return _ir104.NumberOfIROutputPorts; }
}
#endregion
}
}
/// <summary>
/// CEN-IO-IR-104 controller fatory
/// </summary>
public class CenIoIr104ControllerFactory : EssentialsDeviceFactory<CenIoIr104Controller>
{
/// </summary>
public class CenIoIr104ControllerFactory : EssentialsDeviceFactory<CenIoIr104Controller>
{
/// <summary>
/// Constructor
/// </summary>
public CenIoIr104ControllerFactory()
{
TypeNames = new List<string>() { "cenioir104" };
}
/// </summary>
public CenIoIr104ControllerFactory()
{
TypeNames = new List<string>() { "cenioir104" };
}
/// <summary>
/// Build device CEN-IO-IR-104
/// </summary>
/// <param name="dc"></param>
/// <returns></returns>
public override EssentialsDevice BuildDevice(DeviceConfig dc)
{
Debug.Console(1, "Factory Attempting to create new CEN-IO-IR-104 Device");
/// <returns></returns>
public override EssentialsDevice BuildDevice(DeviceConfig dc)
{
Debug.Console(1, "Factory Attempting to create new CEN-IO-IR-104 Device");
var control = CommFactory.GetControlPropertiesConfig(dc);
if (control == null)
{
Debug.Console(1, "Factory failed to create a new CEN-IO-IR-104 Device");
Debug.Console(1, "Factory failed to create a new CEN-IO-IR-104 Device, control properties not found");
return null;
}
var ipid = control.IpIdInt;
}
var ipid = control.IpIdInt;
if(ipid != 0) return new CenIoIr104Controller(dc.Key, dc.Name, new CenIoIr104(ipid, Global.ControlSystem));
Debug.Console(1, "Factory failed to create a new CEN-IO-IR-104 Device using IP-ID-{0}", ipid);
return null;
}
}
return null;
}
}
}