@@ -53,11 +53,14 @@ namespace PepperDash.Essentials
|
||||
// to allow any HD-BaseT DM endpoints to register first.
|
||||
if (Global.ControlSystemIsDmpsType)
|
||||
{
|
||||
Debug.Console(2, "******************* InitializeSystem() Entering **********************");
|
||||
|
||||
_initializeEvent = new CEvent();
|
||||
|
||||
DeviceManager.AllDevicesActivated += (o, a) =>
|
||||
{
|
||||
_initializeEvent.Set();
|
||||
Debug.Console(2, "******************* InitializeSystem() Exiting **********************");
|
||||
};
|
||||
|
||||
_initializeEvent.Wait(30000);
|
||||
|
||||
@@ -46,6 +46,14 @@ namespace PepperDash.Essentials.Core.Bridges
|
||||
public JoinDataComplete RawOccupancyUsFeedback = new JoinDataComplete(new JoinData { JoinNumber = 7, JoinSpan = 1 },
|
||||
new JoinMetadata { Description = "Raw Occupancy Us Feedback", JoinCapabilities = eJoinCapabilities.ToSIMPL, JoinType = eJoinType.Digital });
|
||||
|
||||
[JoinName("IdentityModeOn")]
|
||||
public JoinDataComplete IdentityMode = new JoinDataComplete(new JoinData { JoinNumber = 8, JoinSpan = 1 },
|
||||
new JoinMetadata { Description = "Enable Identity Mode", JoinCapabilities = eJoinCapabilities.FromSIMPL, JoinType = eJoinType.Digital });
|
||||
|
||||
[JoinName("IdentityModeFeedback")]
|
||||
public JoinDataComplete IdentityModeFeedback = new JoinDataComplete(new JoinData { JoinNumber = 8, JoinSpan = 1 },
|
||||
new JoinMetadata { Description = "Identity Mode Feedback", JoinCapabilities = eJoinCapabilities.ToSIMPL, JoinType = eJoinType.Digital });
|
||||
|
||||
[JoinName("EnableLedFlash")]
|
||||
public JoinDataComplete EnableLedFlash = new JoinDataComplete(new JoinData { JoinNumber = 11, JoinSpan = 1 },
|
||||
new JoinMetadata { Description = "Enable Led Flash", JoinCapabilities = eJoinCapabilities.ToFromSIMPL, JoinType = eJoinType.Digital });
|
||||
|
||||
@@ -69,19 +69,28 @@ namespace PepperDash.Essentials.Core
|
||||
public override bool CustomActivate()
|
||||
{
|
||||
Debug.Console(0, this, "Activating");
|
||||
if (!PreventRegistration)
|
||||
{
|
||||
if (!PreventRegistration)
|
||||
{
|
||||
//Debug.Console(1, this, " Does not require registration. Skipping");
|
||||
|
||||
var response = Hardware.RegisterWithLogging(Key);
|
||||
if (response != eDeviceRegistrationUnRegistrationResponse.Success)
|
||||
{
|
||||
//Debug.Console(0, this, "ERROR: Cannot register Crestron device: {0}", response);
|
||||
return false;
|
||||
}
|
||||
var response = Hardware.RegisterWithLogging(Key);
|
||||
if (response != eDeviceRegistrationUnRegistrationResponse.Success)
|
||||
{
|
||||
//Debug.Console(0, this, "ERROR: Cannot register Crestron device: {0}", response);
|
||||
return false;
|
||||
}
|
||||
|
||||
IsRegistered.FireUpdate();
|
||||
}
|
||||
}
|
||||
else
|
||||
{
|
||||
AddPostActivationAction(() =>
|
||||
{
|
||||
var response = Hardware.RegisterWithLogging(Key);
|
||||
|
||||
IsRegistered.FireUpdate();
|
||||
});
|
||||
}
|
||||
|
||||
foreach (var f in Feedbacks)
|
||||
{
|
||||
|
||||
@@ -43,6 +43,17 @@ namespace PepperDash.Essentials.Core
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// True when the processor type is a DMPS 4K variant
|
||||
/// </summary>
|
||||
public static bool ControlSystemIsDmps4kType
|
||||
{
|
||||
get
|
||||
{
|
||||
return ControlSystemIsDmpsType && ControlSystem.ControllerPrompt.ToLower().IndexOf("4k") > -1;
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// The file path prefix to the folder containing configuration files
|
||||
/// </summary>
|
||||
|
||||
@@ -1,6 +1,7 @@
|
||||
using System;
|
||||
using System.Collections.Generic;
|
||||
using System.Linq;
|
||||
using System.Resources;
|
||||
using System.Text;
|
||||
using Crestron.SimplSharp;
|
||||
using Crestron.SimplSharpPro.DeviceSupport;
|
||||
@@ -61,6 +62,8 @@ namespace PepperDash.Essentials.Core
|
||||
|
||||
public BoolFeedback RawOccupancyUsFeedback { get; private set; }
|
||||
|
||||
public BoolFeedback IdentityModeFeedback { get; private set; }
|
||||
|
||||
// Debug properties
|
||||
public bool InTestMode { get; private set; }
|
||||
|
||||
@@ -117,6 +120,8 @@ namespace PepperDash.Essentials.Core
|
||||
|
||||
RawOccupancyUsFeedback = new BoolFeedback(() => OccSensor.RawOccupancyDetectedByUltrasonicSensorFeedback.BoolValue);
|
||||
|
||||
IdentityModeFeedback = new BoolFeedback(()=>OccSensor.IdentityModeOnFeedback.BoolValue);
|
||||
|
||||
UltrasonicSensitivityInVacantStateFeedback = new IntFeedback(() => (int)OccSensor.UltrasonicSensorSensitivityInVacantStateFeedback);
|
||||
|
||||
UltrasonicSensitivityInOccupiedStateFeedback = new IntFeedback(() => (int)OccSensor.UltrasonicSensorSensitivityInOccupiedStateFeedback);
|
||||
@@ -199,6 +204,27 @@ namespace PepperDash.Essentials.Core
|
||||
{
|
||||
SetAndWhenVacatedState((bool)PropertiesConfig.AndWhenVacatedState);
|
||||
}
|
||||
|
||||
// TODO [ ] feature/cenoodtcpoe-sensor-sensitivity-configuration
|
||||
if (PropertiesConfig.UsSensitivityOccupied != null)
|
||||
{
|
||||
SetUsSensitivityOccupied((ushort)PropertiesConfig.UsSensitivityOccupied);
|
||||
}
|
||||
|
||||
if (PropertiesConfig.UsSensitivityVacant != null)
|
||||
{
|
||||
SetUsSensitivityVacant((ushort)PropertiesConfig.UsSensitivityVacant);
|
||||
}
|
||||
|
||||
if (PropertiesConfig.PirSensitivityOccupied != null)
|
||||
{
|
||||
SetPirSensitivityOccupied((ushort)PropertiesConfig.PirSensitivityOccupied);
|
||||
}
|
||||
|
||||
if (PropertiesConfig.PirSensitivityVacant != null)
|
||||
{
|
||||
SetPirSensitivityVacant((ushort)PropertiesConfig.PirSensitivityVacant);
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
@@ -279,7 +305,21 @@ namespace PepperDash.Essentials.Core
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// <summary>
|
||||
/// Sets the identity mode on or off
|
||||
/// </summary>
|
||||
/// <param name="state"></param>
|
||||
public void SetIdentityMode(bool state)
|
||||
{
|
||||
if (state)
|
||||
OccSensor.IdentityModeOn();
|
||||
else
|
||||
OccSensor.IdentityModeOff();
|
||||
|
||||
Debug.Console(1, this, "Identity Mode: {0}", OccSensor.IdentityModeOnFeedback.BoolValue ? "On" : "Off");
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Enables or disables the PIR sensor
|
||||
/// </summary>
|
||||
/// <param name="state"></param>
|
||||
@@ -506,6 +546,54 @@ namespace PepperDash.Essentials.Core
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Sets the US sensor sensitivity for occupied state
|
||||
/// </summary>
|
||||
/// <param name="sensitivity"></param>
|
||||
public void SetUsSensitivityOccupied(ushort sensitivity)
|
||||
{
|
||||
var level = (eSensitivityLevel) sensitivity;
|
||||
if (level == 0) return;
|
||||
|
||||
OccSensor.UltrasonicSensorSensitivityInOccupiedState = level;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Sets the US sensor sensitivity for vacant state
|
||||
/// </summary>
|
||||
/// <param name="sensitivity"></param>
|
||||
public void SetUsSensitivityVacant(ushort sensitivity)
|
||||
{
|
||||
var level = (eSensitivityLevel)sensitivity;
|
||||
if (level == 0) return;
|
||||
|
||||
OccSensor.UltrasonicSensorSensitivityInVacantState = level;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Sets the PIR sensor sensitivity for occupied state
|
||||
/// </summary>
|
||||
/// <param name="sensitivity"></param>
|
||||
public void SetPirSensitivityOccupied(ushort sensitivity)
|
||||
{
|
||||
var level = (eSensitivityLevel)sensitivity;
|
||||
if (level == 0) return;
|
||||
|
||||
OccSensor.PassiveInfraredSensorSensitivityInOccupiedState = level;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Sets the PIR sensor sensitivity for vacant state
|
||||
/// </summary>
|
||||
/// <param name="sensitivity"></param>
|
||||
public void SetPirSensitivityVacant(ushort sensitivity)
|
||||
{
|
||||
var level = (eSensitivityLevel)sensitivity;
|
||||
if (level == 0) return;
|
||||
|
||||
OccSensor.PassiveInfraredSensorSensitivityInVacantState = level;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Method to print current settings to console
|
||||
/// </summary>
|
||||
@@ -647,8 +735,11 @@ namespace PepperDash.Essentials.Core
|
||||
|
||||
//Sensor Raw States
|
||||
occController.RawOccupancyPirFeedback.LinkInputSig(trilist.BooleanInput[joinMap.RawOccupancyPirFeedback.JoinNumber]);
|
||||
occController.RawOccupancyUsFeedback.LinkInputSig(trilist.BooleanInput[joinMap.RawOccupancyUsFeedback.JoinNumber]);
|
||||
|
||||
occController.RawOccupancyUsFeedback.LinkInputSig(trilist.BooleanInput[joinMap.RawOccupancyUsFeedback.JoinNumber]);
|
||||
|
||||
// Identity mode
|
||||
trilist.SetBoolSigAction(joinMap.IdentityMode.JoinNumber, occController.SetIdentityMode);
|
||||
occController.IdentityModeFeedback.LinkInputSig(trilist.BooleanInput[joinMap.IdentityModeFeedback.JoinNumber]);
|
||||
}
|
||||
|
||||
public class CenOdtOccupancySensorBaseControllerFactory : EssentialsDeviceFactory<CenOdtOccupancySensorBaseController>
|
||||
|
||||
@@ -47,5 +47,35 @@ namespace PepperDash.Essentials.Core
|
||||
|
||||
[JsonProperty("andWhenVacatedState")]
|
||||
public bool? AndWhenVacatedState { get; set; }
|
||||
|
||||
// PoE Sensors: CenOdtCPoe
|
||||
|
||||
/// <summary>
|
||||
/// Sets the sensitivity level for US while sensor is in occupied state
|
||||
/// 1 = low; 2 = medium; 3 = high; 4 = xlow; 5 = 2xlow; 6 = 3xlow
|
||||
/// </summary>
|
||||
[JsonProperty("usSensitivityOccupied")]
|
||||
public ushort? UsSensitivityOccupied { get; set; }
|
||||
|
||||
/// <summary>
|
||||
/// Sets the sensitivity level for US while sensor is in vacant state
|
||||
/// 1 = low; 2 = medium; 3 = high; 4 = xlow; 5 = 2xlow; 6 = 3xlow
|
||||
/// </summary>
|
||||
[JsonProperty("usSensitivityVacant")]
|
||||
public ushort? UsSensitivityVacant { get; set; }
|
||||
|
||||
/// <summary>
|
||||
/// Sets the sensitivity level for PIR while sensor is in occupied state
|
||||
/// 1 = low; 2 = medium; 3 = high
|
||||
/// </summary>
|
||||
[JsonProperty("pirSensitivityOccupied")]
|
||||
public ushort? PirSensitivityOccupied { get; set; }
|
||||
|
||||
/// <summary>
|
||||
/// Sets the sensitivity level for PIR while sensor is in vacant state
|
||||
/// 1 = low; 2 = medium; 3 = high
|
||||
/// </summary>
|
||||
[JsonProperty("pirSensitivityVacant")]
|
||||
public ushort? PirSensitivityVacant { get; set; }
|
||||
}
|
||||
}
|
||||
@@ -1285,7 +1285,10 @@ namespace PepperDash.Essentials.DM
|
||||
|
||||
var output = outputSelector as DMOutput;
|
||||
|
||||
if (output == null)
|
||||
var isUsbInput = (sigType & eRoutingSignalType.UsbInput) == eRoutingSignalType.UsbInput;
|
||||
var isUsbOutput = (sigType & eRoutingSignalType.UsbOutput) == eRoutingSignalType.UsbOutput;
|
||||
|
||||
if (output == null && !(isUsbOutput || isUsbInput))
|
||||
{
|
||||
Debug.Console(0, this, Debug.ErrorLogLevel.Warning,
|
||||
"Unable to execute switch for inputSelector {0} to outputSelector {1}", inputSelector,
|
||||
@@ -1316,7 +1319,10 @@ namespace PepperDash.Essentials.DM
|
||||
if ((sigType & eRoutingSignalType.Video) == eRoutingSignalType.Video)
|
||||
{
|
||||
Chassis.VideoEnter.BoolValue = true;
|
||||
output.VideoOut = input; //Chassis.Outputs[output].VideoOut = inCard;
|
||||
if (output != null)
|
||||
{
|
||||
output.VideoOut = input; //Chassis.Outputs[output].VideoOut = inCard;
|
||||
}
|
||||
}
|
||||
|
||||
if ((sigType & eRoutingSignalType.Audio) == eRoutingSignalType.Audio)
|
||||
@@ -1326,17 +1332,66 @@ namespace PepperDash.Essentials.DM
|
||||
{
|
||||
dmMdMnxn.AudioEnter.BoolValue = true;
|
||||
}
|
||||
output.AudioOut = input;
|
||||
//Chassis.Outputs[output].AudioOut = inCard;
|
||||
if (output != null)
|
||||
{
|
||||
output.AudioOut = input;
|
||||
}
|
||||
}
|
||||
|
||||
if ((sigType & eRoutingSignalType.UsbOutput) == eRoutingSignalType.UsbOutput || (sigType & eRoutingSignalType.UsbInput) == eRoutingSignalType.UsbInput)
|
||||
if ((sigType & eRoutingSignalType.UsbOutput) == eRoutingSignalType.UsbOutput)
|
||||
|
||||
{
|
||||
Chassis.USBEnter.BoolValue = true;
|
||||
output.USBRoutedTo = input;
|
||||
Chassis.USBEnter.BoolValue = true;
|
||||
if (inputSelector == null && output != null)
|
||||
{
|
||||
//clearing the route is intended
|
||||
output.USBRoutedTo = null;
|
||||
return;
|
||||
}
|
||||
|
||||
if (inputSelector != null && input == null)
|
||||
{
|
||||
//input selector is DMOutput...we're doing a out to out route
|
||||
var tempInput = inputSelector as DMOutput;
|
||||
|
||||
if (tempInput == null || output == null)
|
||||
{
|
||||
return;
|
||||
}
|
||||
output.USBRoutedTo = tempInput;
|
||||
return;
|
||||
}
|
||||
|
||||
if (input != null & output != null)
|
||||
{
|
||||
output.USBRoutedTo = input;
|
||||
}
|
||||
}
|
||||
|
||||
if((sigType & eRoutingSignalType.UsbInput) != eRoutingSignalType.UsbInput)
|
||||
{
|
||||
return;
|
||||
}
|
||||
|
||||
Chassis.USBEnter.BoolValue = true;
|
||||
if (output != null)
|
||||
{
|
||||
output.USBRoutedTo = input;
|
||||
return;
|
||||
}
|
||||
var tempOutput = outputSelector as DMInput;
|
||||
|
||||
if (tempOutput == null)
|
||||
{
|
||||
Debug.Console(0, this, Debug.ErrorLogLevel.Warning,
|
||||
"Unable to execute switch for inputSelector {0} to outputSelector {1}", inputSelector,
|
||||
outputSelector);
|
||||
return;
|
||||
}
|
||||
|
||||
tempOutput.USBRoutedTo = input;
|
||||
}
|
||||
|
||||
#endregion
|
||||
|
||||
#region IRoutingNumeric Members
|
||||
@@ -1349,8 +1404,10 @@ namespace PepperDash.Essentials.DM
|
||||
|
||||
DMInputOutputBase dmCard;
|
||||
|
||||
//Routing Input to Input or Output to Input
|
||||
if ((sigType & eRoutingSignalType.UsbInput) == eRoutingSignalType.UsbInput)
|
||||
{
|
||||
Debug.Console(2, this, "Executing USB Input switch.\r\n in:{0} output: {1}", inputSelector, outputSelector);
|
||||
if (outputSelector > chassisSize)
|
||||
{
|
||||
uint outputIndex;
|
||||
@@ -1370,13 +1427,14 @@ namespace PepperDash.Essentials.DM
|
||||
dmCard = Chassis.Inputs[inputSelector];
|
||||
}
|
||||
|
||||
ExecuteSwitch(dmCard, Chassis.Outputs[outputSelector], sigType);
|
||||
ExecuteSwitch(dmCard, Chassis.Inputs[outputSelector], sigType);
|
||||
return;
|
||||
}
|
||||
if ((sigType & eRoutingSignalType.UsbOutput) == eRoutingSignalType.UsbOutput)
|
||||
{
|
||||
Debug.Console(2, this, "Executing USB Output switch.\r\n in:{0} output: {1}", inputSelector, outputSelector);
|
||||
|
||||
//routing Output to Output or Input to Output
|
||||
if (inputSelector > chassisSize)
|
||||
{
|
||||
//wanting to route an output to an output. Subtract chassis size and get output, unless it's 8x8
|
||||
|
||||
@@ -36,7 +36,7 @@ namespace PepperDash.Essentials.DM
|
||||
var ipid = props.Control.IpIdInt;
|
||||
var pKey = props.ParentDeviceKey.ToLower();
|
||||
|
||||
if (pKey == "processor")
|
||||
if (pKey == "processor")
|
||||
{
|
||||
// Catch constructor failures, mainly dues to IPID
|
||||
try
|
||||
@@ -70,7 +70,7 @@ namespace PepperDash.Essentials.DM
|
||||
|
||||
var parentDev = DeviceManager.GetDeviceForKey(pKey);
|
||||
DMInput dmInput;
|
||||
bool noIpId = false;
|
||||
bool isCpu3 = false;
|
||||
|
||||
if (parentDev is IDmSwitch)
|
||||
{
|
||||
@@ -96,7 +96,7 @@ namespace PepperDash.Essentials.DM
|
||||
chassis is DmMd16x16Cpu3rps || chassis is DmMd32x32Cpu3rps ||
|
||||
chassis is DmMd128x128 || chassis is DmMd64x64)
|
||||
{
|
||||
noIpId = true;
|
||||
isCpu3 = true;
|
||||
}
|
||||
|
||||
}
|
||||
@@ -116,7 +116,6 @@ namespace PepperDash.Essentials.DM
|
||||
}
|
||||
|
||||
dmpsDev.TxDictionary.Add(num, key);
|
||||
noIpId = dmpsDev.Dmps4kType;
|
||||
|
||||
try
|
||||
{
|
||||
@@ -138,7 +137,7 @@ namespace PepperDash.Essentials.DM
|
||||
try
|
||||
{
|
||||
// Must use different constructor for CPU3 or DMPS3-4K types. No IPID
|
||||
if (noIpId)
|
||||
if (isCpu3 || Global.ControlSystemIsDmps4kType)
|
||||
{
|
||||
if (typeName.StartsWith("dmtx200"))
|
||||
return new DmTx200Controller(key, name, new DmTx200C2G(dmInput));
|
||||
@@ -222,11 +221,12 @@ namespace PepperDash.Essentials.DM
|
||||
protected DmTxControllerBase(string key, string name, EndpointTransmitterBase hardware)
|
||||
: base(key, name, hardware)
|
||||
{
|
||||
// if wired to a chassis, skip registration step in base class
|
||||
if (hardware.DMInput != null)
|
||||
{
|
||||
this.PreventRegistration = true;
|
||||
}
|
||||
// if wired to a chassis or DMPS, skip registration step in base class
|
||||
if (hardware.DMInput != null || (Global.ControlSystemIsDmpsType && hardware.DMInput != null))
|
||||
{
|
||||
this.PreventRegistration = true;
|
||||
}
|
||||
|
||||
AddToFeedbackList(ActiveVideoInputFeedback);
|
||||
}
|
||||
|
||||
|
||||
@@ -298,6 +298,13 @@ namespace PepperDash.Essentials.Devices.Common.VideoCodec
|
||||
}
|
||||
|
||||
LinkVideoCodecToApi(codec, trilist, joinMap);
|
||||
|
||||
trilist.OnlineStatusChange += (device, args) =>
|
||||
{
|
||||
if (!args.DeviceOnLine) return;
|
||||
|
||||
trilist.SetString(joinMap.Schedule.JoinNumber, "\xFC");
|
||||
};
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
@@ -785,6 +792,16 @@ ScreenIndexIsPinnedTo: {8} (a{17})
|
||||
|
||||
_currentMeetings = codec.CodecSchedule.Meetings.Where(m => m.StartTime >= currentTime || m.EndTime >= currentTime).ToList();
|
||||
|
||||
if (_currentMeetings.Count == 0)
|
||||
{
|
||||
var emptyXSigByteArray = XSigHelpers.ClearOutputs();
|
||||
var emptyXSigString = Encoding.GetEncoding(XSigEncoding)
|
||||
.GetString(emptyXSigByteArray, 0, emptyXSigByteArray.Length);
|
||||
|
||||
trilist.SetString(joinMap.Schedule.JoinNumber, emptyXSigString);
|
||||
return;
|
||||
}
|
||||
|
||||
var meetingsData = UpdateMeetingsListXSig(_currentMeetings);
|
||||
trilist.SetString(joinMap.Schedule.JoinNumber, meetingsData);
|
||||
trilist.SetUshort(joinMap.MeetingCount.JoinNumber, (ushort)_currentMeetings.Count);
|
||||
|
||||
@@ -1306,11 +1306,16 @@ namespace PepperDash.Essentials.Devices.Common.VideoCodec.ZoomRoom
|
||||
var codecBookings = JsonConvert.DeserializeObject<List<zCommand.BookingsListResult>>(
|
||||
responseObj.ToString());
|
||||
|
||||
if (codecBookings != null && codecBookings.Count > 0)
|
||||
{
|
||||
CodecSchedule.Meetings = zCommand.GetGenericMeetingsFromBookingResult(
|
||||
codecBookings, CodecSchedule.MeetingWarningMinutes);
|
||||
}
|
||||
if (codecBookings != null && codecBookings.Count > 0)
|
||||
{
|
||||
CodecSchedule.Meetings = zCommand.GetGenericMeetingsFromBookingResult(
|
||||
codecBookings, CodecSchedule.MeetingWarningMinutes);
|
||||
}
|
||||
else
|
||||
{
|
||||
//need to clear the list if it's empty
|
||||
CodecSchedule.Meetings = new List<Meeting>();
|
||||
}
|
||||
|
||||
break;
|
||||
}
|
||||
|
||||