In some scenarios when working with NVX, a route is intended to use the
secondary audio (NAX) path instead of the primary audio path. A route
that's both `Video` and `SecondaryAudio` should be considered a
dual-path route instead of a single path.
Added the `ILightingScenesDynamic` interface to add an event for devices that support retrieving scene data from the lighting system at runtime. Also added the `sortOrder` property for the `LightingScene` type to allow for control over the sort order of scenes on the UI
Due to how the `BeginPolling` method was written and being called, there
were situations where multiple PollTimers were created, causing there to
be multiple messages sent to the end point for each poll cycle.
In order to match up with how existing front-end apps are expecting to
recieve data for devices that implement the `IHasInputs<T>` interface,
there is now an IHasInputsMessengers that is implemented for devices
that implement `IHasInputs<string>`, `IHasInputs<int>` or
`IHasInputs<byte>` interfaces.
In order to satisfy the requirements for the `MessengerBase` class, the
`ISelectableItemsMessenger` class needs to take an `IHasInputs<T>`, as that is
the device that implements `IKeyName`. We may want to consider adding a
`IHasInputsMessenger` specifically for those devices that implement that
interface vs the `ISelectableItemsMessenger`.
`CrestronGenericBaseDevice` was NOT calling `base.CustomActivate()` in
it's `CustomActivate` override, causing the
`CreateMobileControlMessengers` method to not be called as expected when
plugin devices were inheriting from `CrestronGenericBaseDevice` or
`CrestronGenericBridgeableBaseDevice`.
If the grant code was not provided, the `mobileadduiclient` console
command would fail silently. The command now checks that the correct
number of arguments was provided and prints an error to the console of
one is missing
In an effort to make things easier for devs and end users, the plugin loading logic will now find .cplz files that are in the `Global.FilePathPrefix` base folder (/user/program{programNumber}/` on an appliance, `/user/` on a server). The same applies for IR files. This should make it so that individual plugin cplzs can be loaded via the VC-4 web interface.
The TielineConfig had no property for the `type` property from an Essentials configuration file to be deserialized into. This has been corrected so that the `type` property in a Tieline JSON configuration is now respected and used to build the tieline.
The `RoutingPortCollection` type appears to not be currently
serializable. If a class that contains this collection is going to be
serialized, the collection should have the `JsonIgnore` attribute added.
If the list is needed, use a conversion object and convert it to a
regular list.